Showing results: 46 - 60 of 203 items found.
-
Precise Time and Frequency, Inc.
The ptf 1202A High Frequency Distribution amplifier provides high performance frequency references for laboratory or system use requiring distribution at frequencies of 30MHz and above.The ptf 1202A is especially designed to distribute the high frequency input signal to 12 separate outputs, with minimum signal distortion and maximum isolation between individual output signals.
-
Quartzlock (UK) Ltd.
Our range of precise low noise rubidium oscillators in a variety of sizes to suit all appliations. These acurate frequency references are used in telecoms, aviation, nautical and precision test and measurement enviroments.
-
5174 -
Abaco Systems Inc
The 5174 provides two major functions, serving as a precision Voltage Controlled oscillator board and a variable frequency source board. These features can be use together or independently. As a variable frequency source, the 5174 provides a high-resolution variable clock source that is based upon a reference clock supplied by the ECM carrier.
-
Lisun Electronics Inc.
CFL testing instruments of Lisun Group includes: High Frequency Fluorescent Lamp Test, Adjustable Reference Ballast, Digital Torsion Meter, Multiplex temperature tester, Lamp cap gauge, etc.
-
RESON TC 4040 -
Teledyne Marine RESON B.V.
The TC4040 is an ideal standard reference hydrophone for calibration of transducers, hydrophones and underwater acoustic measurement systems.The TC4040 offers flat frequency receiving response over a wide frequency range and the relatively high transmitting sensitivity makes it very useful within many areas of underwater acoustic research, tests and measurements.
-
RESON TC 4038 -
Teledyne Marine RESON B.V.
The TC4038 is a miniature probe hydrophone, specifically designed as a standard reference hydrophone for high frequencies in the range: 100kHz to 1.2MHz. The TC4038 provides a flat frequency response and omnidirectional characteristics in the specified frequency range. The sensor element has excellent stability, which ensures reliable sensitivity over long periods of time.
-
VME635091-SyncClock -
Brandywine Communications
Brandywine Communications’ VME635091-SYNCCLOCK is a time and frequency processor module that provides precision time and frequency reference to the host computer and peripheral data acquisition systems. Time is acquired from time code signals, typically IRIG B. Time is displayed on the front panel (hours, minutes, seconds) via LED digits.
-
PERF10 -
Stanford Research Systems, Inc.
Perfection is a high standard - but your studio clocks deserve nothing less. That''s why we designed the PERF10, to offer audio professionals and demanding audiophiles a frequency reference of staggering accuracy and unmatched stability.
-
SK4M Series -
Micran Co. Ltd.
*Frequency range: 100 Hz to 20/50 GHz*DANL < −165 dBm/Hz*Low Phase Noise −125 dBc/Hz at 1 GHz signal from 100 kHz offset*High Frequency Reference Accuracy ±0.1 ppm*Resolution Bandwidth Range 1 Hz to 10 MHz*Built-in Low-noise Amplifier
-
Muquans, SAS
This equipment is a stand-alone device that enables to coherently regenerate an optical signal allowing long-haul dissemination of an ultra-stable optical frequency reference. Its architecture is based on the heterodyne phase-locking of a narrow spectral width laser diode on the reference signal. The station is equipped with low phase noise optical interferometer that perform a thorough characterization of the phase noise accumulated by the incoming signal, and a compensation system of this phase noise.
-
PSPL01 -
Pyle Audio Inc.
Frequency Range: 31.5 Hz-8 KHzMeasuring Level Range: 40 to 130 dBAccuracy: +/- 3.5dB @ 1 kHz, 94dB (Under Reference Conditions)1/2" Electret Condenser MicrophoneNewly Designed HousingC-type Frequency WeightingHigh Performance & Auto LCD Backlight50 hrs. Battery LifeAuto Power Off (15 Minutes Inactivity)Sold as : Unit
-
FRF -
Crystal instruments
FFT Spectral Analysis. Frequency Response Function (FRF) is a commonly used measurement type of the Dynamic Signal Analyzer. FRF is defined as the ratio of response i.e. acceleration, velocity, or displacement with respect to the excitation force which is the reference.
-
Precision Test Systems Ltd.
A complete range of distribution amplifiers are manufactured by Precision Test Systems. A distribution amplifier is used to distribute the output of a frequency reference to many different places. Usually the frequency is 5 or 10 MHz but we manufacture distribution amps from DC to over 2000 MHz. We make some of the industries lowest phase noise products.
-
AD-100 -
Com-Power Corporation
The Tuned Dipole Antenna model AD-100 is a reference antenna set specified in many EMC standards. It is used in the frequency range of 30 MHz to 1 GHz. This set consists of four baluns and was designed according to American National Standard C63.4. This reference antenna set is used for EMC test site calibrations and for calibrating other antennas, because it is considered a standard antenna according to ANSI C63.5 standard.
-
Precise Time and Frequency, Inc.
The ptf 2210A Quartz Frequency Standard has been designed to provide a highly stable and spectrally pure frequency reference for applications requiring the ultimate in short term frequency performance.The instrument contains a double oven controlled stress compensated (SC cut) quartz crystal oscillator (OCXO) to give the ultimate in performance.Ideal for laboratory or system use, the unit provides good stability performance at lower cost and with improved phase noise.